Watech 5000 – 5 kW Small Wind Turbine

5,000 W direct-drive small wind turbine for larger residences and agriculture. 3.84 m rotor, 3 m/s cut-in, smart PCB control, three-stage braking and remote monitoring — off-grid and hybrid-ready.

350.000₺ /pc
Stokta
Toplam Fiyat 350.000₺
Stok gelince haber verelim

Bu ürün şu an tükendi. Tekrar stoğa girdiğinde size e-posta gönderelim.

Tahmini teslimat: 3-6 iş günü (yurt içi)
Satın alımdan itibaren 14 gün içinde koşulsuz iade

Watech 5000 (5 kW) — Sustainable Energy Should Be Uninterrupted

Designed for homes and small businesses looking to reduce electricity costs and strengthen their energy independence, Watech combines direct-drive permanent magnet generator technology, an intelligent PCB-based control system, multi-layer safety architecture, and remote monitoring to deliver reliable, efficient, and sustainable wind power.

5,000 WRated power
3.84 mRotor diameter
3 m/sCut-in wind speed
15 m/sCut-out wind speed
37.5 m/sSurvival wind speed
Low NoiseOptimized blade design for quiet operation.
DurableBuilt to withstand harsh weather conditions with a long-lasting structure.
High EfficiencyMaximum energy generation even in low wind conditions.
Eco-FriendlyProduces clean energy and reduces your carbon footprint.

The Watech platform

Watech is an intelligent small wind turbine family engineered for residential, agricultural, and off-grid applications — available in 3 kW, 5 kW, and 7 kW configurations for scalable energy independence. Every system pairs a direct-drive permanent magnet generator with aerodynamic fiberglass blades and a multi-layer safety architecture — combining electronic braking, mechanical disc braking, and manual emergency stop for dependable operation in changing wind conditions.

  • Direct Drive — gearless permanent magnet technology
  • Smart PCB — real-time intelligent control
  • Remote Monitoring — live system data, performance tracking, alerts and remote diagnostics
  • Hybrid Ready — designed for solar and battery systems

IP54 protection · 3+2 years warranty · 20 years design life. Reliable. Intelligent. Continuous. Transforming Wind Into Energy Continuity — Designed in Germany.

See the tabs for the full datasheet, power curve, control & safety, installation and warranty details.

Watech 5000 technical specifications

General & Performance

ModelTijiwa Watech 5000
Turbine typeHorizontal-axis small wind turbine (HAWT)
Rated power5,000 W
Rated rotor speed300 rpm
Maximum rotor speed330 rpm
Cut-in wind speed3 m/s
Controlled stop / cut-out15 m/s
Design wind classIEC Class III - 37.5 m/s
Design life20 years
ApplicationsResidential, agriculture, off-grid and hybrid systems

Rotor & Aerodynamics

Rotor diameter3.84 m
Swept area11.58 m²
Blade count3
Blade length1.85 m
Blade weight4.3 kg each
Blade materialFibreglass composite
Fibre systemRandom + directional fibreglass
ManufacturingHand lay-up / moulded production
AirfoilSelig S814 / S822-derived profile
Surface protectionUV-resistant epoxy coating

Mechanical Construction

Turbine massApprox. 128 kg
Rotor assembly massApprox. 13.3 kg
Nacelle materialETIAL 160 aluminium
Protective finishOven-cured coating
Enclosure ratingIP54 (nacelle)
Corrosion protectionStandard atmospheric; coastal option available
Acoustic levelApprox. 45 dB(A) at 10 m, wind-dependent

Generator & Electrical Output

Generator typeDirect-drive permanent-magnet alternator
Magnet gradeN35
Rotor / stator1040 steel rotor / laminated steel stator
WindingsInsulated copper conductors
BearingsORS single- and double-row ball bearings
Generator efficiencyUp to 89%
OutputVariable 3-phase AC
Winding options48-400 V, configuration-dependent

Performance values are preliminary and site-dependent; final configuration may vary by winding, controller, tower and project.

Watech 5000 power curve

Electrical output across the operating wind-speed range.

0100020003000400050003456789101112131415Wind speed (m/s)Electrical power (W)
Wind speed (m/s)345678910111213
Electrical power (W)701603105408501,2501,7502,4003,1504,1005,000
3 m/sCut-in wind speed
5 – 7 m/sTypical operating range
5,000 WRated power at 13 m/s
15 m/sControlled stop / cut-out

Estimated yield · Watech 5000

Estimated annual production6,000–7,000 kWh
Estimated annual savings€2,200–3,000
Typical payback period4–7 years
Recommended forLarger residences & agriculture

Power curve, production and savings figures are preliminary estimates; actual results depend on site wind conditions, tower height, configuration and local electricity prices.

Smart control

A custom PCB controller manages charging, braking and protection; the turbine is designed for off-grid and hybrid-ready systems.

Smart PCB Control System

Controller architectureCustom PCB-based wind energy controller
Maximum turbine input5 kW controller class
Generator inputVariable 3-phase AC
DC conversionIntegrated rectification / system interface
Battery systemsLi-ion, LiFePO4 and lead-acid, configuration-dependent
Dump-load outputSystem-sized resistive, air-cooled
CoolingTemperature-controlled fan
Protection functionsOvervoltage, overcurrent, overtemperature and overspeed
Control logicVoltage, wind, temperature, current and rotor-speed control
ExpansionOptional dual-turbine mode; independent metering and control for each turbine input
Matching controllerSmart Charge Controller SCC-5000

System Architecture

Energy flowTurbine > rectifier > PCB controller > battery/dump load > inverter
Operating modeOff-grid or hybrid-ready operation; no on-grid functionality included
Yaw orientationPassive tail-vane yaw; automatic alignment with wind direction
Hybrid compatibilityCompatible with solar and battery systems
Package scopeTurbine, PCB controller and dump-load as configured; tower optional and project-specific
Not includedSolar panels, batteries, inverter and project-specific cabling unless expressly included in the commercial quotation or sales contract

Multi-layer safety

Electronic braking, mechanical disc braking and manual emergency stop with automatic fail-safe protection logic.

Braking & Safety

Stage 1Magnetic / electrical braking for controlled deceleration
Stage 2Mechanical disc brake, 120 Nm
Stage 3Manual emergency stop
Brake behaviourAutomatic fail-safe protection logic
Control priorityManual stop > overvoltage > wind > temperature > current
Slip-ring system15-channel, 400 VAC, IP54
Insulation resistance>100 MΩ

Compliance status

Designed with reference to IEC 61400-2; EU framework includes LVD 2014/35/EU, EMC 2014/30/EU and Machinery Directive where applicable. Final CE/TÜV status depends on configuration; manufacturing-partner ISO certificates must be valid and verified.

Standards & certifications: IEC 61400-2 · CE · ISO 9001:2015 · IP54 · EMC · LVD · TÜV NORD

CE documentationTechnical datasheet (TIJ-W5000-DS-EN)

Sensors & remote monitoring

Sensor & Data Inputs

  • Wind speed and wind direction
  • Ambient temperature, humidity and barometric pressure
  • Rotor speed via rotary encoder
  • Generator voltage, current and real-time output power
  • Generator and controller temperature
  • Air-density inputs for adaptive operating logic

Remote Monitoring

  • Ethernet-based remote access through the Tijiwa monitoring platform
  • RPM, wind speed, temperature, brake status, fault and event logs
  • Instantaneous, daily and monthly energy production statistics
  • Adjustable data intervals; configurable local retention
  • CSV and API export options

Installation & tower

Good engineering starts before installation: every Watech project begins with a pre-installation site assessment.

Optional Tower System

InstallationGround-mounted tower only; rooftop installation not permitted
Tower optionsProject-specific lattice or cylindrical tower
Reference option11 m S235JR lattice tower
Reference massApprox. 245 kg
AnchoringM24 anchor system
FoundationPreliminary 1.5 x 1.5 x 1.5 m; structural verification required
Site assessmentWind potential, turbulence, tower height and soil conditions must be determined through project-specific structural and geotechnical calculations
Engineering noteLocal structural approval required
Tower heights12 – 24 m, chosen per site analysis

Site selection principles

  • Obstacle assessment — map buildings, trees and terrain that disturb wind flow.
  • Correct tower height — keep the rotor above turbulent airflow.
  • Prevailing wind direction — align placement with the dominant wind.
  • Ground conditions — choose stable ground for lasting foundations.
  • Optimal placement — prefer open areas with uninterrupted wind.

Installation process

  1. Site survey
    Wind potential, turbulence, obstacles, tower height and soil are assessed.
  2. Foundation
    Excavation, anchors and concrete are executed as one engineered base.
  3. Tower
    The tower is lifted, aligned and secured by professional installation teams with controlled on-site assembly.
  4. Turbine
    Generator, rotor and electrical connections are installed, verified and prepared for commissioning.
  5. Electrical integration
    Controller, battery, dump load and inverter are connected.
  6. Commissioning
    The system is tested and handed over for energy production.

Warranty & support

Your power. Our responsibility. Every Tijiwa Watech wind turbine is covered by a 3-year limited warranty program.

Warranty terms

  • Standard warranty: 3 years from the installation date.
  • Optional extension: additional 2 years, subject to contract, commissioning and maintenance conditions.
  • Covers manufacturing defects and material faults; includes repair or replacement of defective parts.
  • Does not cover damages caused by improper installation, misuse, natural disasters or unauthorized modifications.
  • Regular maintenance as per user manual is required for warranty validity.
  • Design life: 20 years under specified operating conditions; warranty period and design life are separate values.

After-sales service

  • Remote support — our technical team monitors your system remotely and provides fast diagnosis and solutions.
  • Preventive maintenance — scheduled inspections and maintenance extend the life of your system and prevent issues before they occur.
  • Fast response — quick response times and efficient solutions to minimize any downtime.
  • Spare parts supply — genuine Tijiwa spare parts are always available to ensure continuous performance.
  • Warranty support — we manage the entire warranty process smoothly and transparently.

Document & contact

DocumentTIJ-W5000-DS-EN | Revision R03 | Issue date 07/2026
Product ownerTijiwa GmbH
AddressAlte Gerberei 4, 35398 Gießen / Hessen, Germany
Contact[email protected] · www.tijiwa.com

Ürün Soruları (0)

Yanıtımızı e-posta ile göndereceğiz. Giriş yaparsanız sorularınızı hesabınızdan takip edebilirsiniz.

Diğer Sorular

Henüz soru sorulmadı

Yorumlar ve Puanlar

0.0 / 5.0
(0 Değerlendirmeler)
Bu ürün için henüz yorum yapılmamış.

Çok Satanlar

Son aramalar
Ürünlerde aranıyor...

Aramanızla eşleşen ürün bulunamadı

Farklı anahtar kelimeler deneyin

Hesabım