Designed for homes and small businesses looking to reduce electricity costs and strengthen their energy independence, Watech combines direct-drive permanent magnet generator technology, an intelligent PCB-based control system, multi-layer safety architecture, and remote monitoring to deliver reliable, efficient, and sustainable wind power.
Watech is an intelligent small wind turbine family engineered for residential, agricultural, and off-grid applications — available in 3 kW, 5 kW, and 7 kW configurations for scalable energy independence. Every system pairs a direct-drive permanent magnet generator with aerodynamic fiberglass blades and a multi-layer safety architecture — combining electronic braking, mechanical disc braking, and manual emergency stop for dependable operation in changing wind conditions.
IP54 protection · 3+2 years warranty · 20 years design life. Reliable. Intelligent. Continuous. Transforming Wind Into Energy Continuity — Designed in Germany.
See the tabs for the full datasheet, power curve, control & safety, installation and warranty details.
| Model | Tijiwa Watech 5000 |
|---|---|
| Turbine type | Horizontal-axis small wind turbine (HAWT) |
| Rated power | 5,000 W |
| Rated rotor speed | 300 rpm |
| Maximum rotor speed | 330 rpm |
| Cut-in wind speed | 3 m/s |
| Controlled stop / cut-out | 15 m/s |
| Design wind class | IEC Class III - 37.5 m/s |
| Design life | 20 years |
| Applications | Residential, agriculture, off-grid and hybrid systems |
| Rotor diameter | 3.84 m |
|---|---|
| Swept area | 11.58 m² |
| Blade count | 3 |
| Blade length | 1.85 m |
| Blade weight | 4.3 kg each |
| Blade material | Fibreglass composite |
| Fibre system | Random + directional fibreglass |
| Manufacturing | Hand lay-up / moulded production |
| Airfoil | Selig S814 / S822-derived profile |
| Surface protection | UV-resistant epoxy coating |
| Turbine mass | Approx. 128 kg |
|---|---|
| Rotor assembly mass | Approx. 13.3 kg |
| Nacelle material | ETIAL 160 aluminium |
| Protective finish | Oven-cured coating |
| Enclosure rating | IP54 (nacelle) |
| Corrosion protection | Standard atmospheric; coastal option available |
| Acoustic level | Approx. 45 dB(A) at 10 m, wind-dependent |
| Generator type | Direct-drive permanent-magnet alternator |
|---|---|
| Magnet grade | N35 |
| Rotor / stator | 1040 steel rotor / laminated steel stator |
| Windings | Insulated copper conductors |
| Bearings | ORS single- and double-row ball bearings |
| Generator efficiency | Up to 89% |
| Output | Variable 3-phase AC |
| Winding options | 48-400 V, configuration-dependent |
Performance values are preliminary and site-dependent; final configuration may vary by winding, controller, tower and project.
Electrical output across the operating wind-speed range.
| Wind speed (m/s) | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Electrical power (W) | 70 | 160 | 310 | 540 | 850 | 1,250 | 1,750 | 2,400 | 3,150 | 4,100 | 5,000 |
| Estimated annual production | 6,000–7,000 kWh |
|---|---|
| Estimated annual savings | €2,200–3,000 |
| Typical payback period | 4–7 years |
| Recommended for | Larger residences & agriculture |
Power curve, production and savings figures are preliminary estimates; actual results depend on site wind conditions, tower height, configuration and local electricity prices.
A custom PCB controller manages charging, braking and protection; the turbine is designed for off-grid and hybrid-ready systems.
| Controller architecture | Custom PCB-based wind energy controller |
|---|---|
| Maximum turbine input | 5 kW controller class |
| Generator input | Variable 3-phase AC |
| DC conversion | Integrated rectification / system interface |
| Battery systems | Li-ion, LiFePO4 and lead-acid, configuration-dependent |
| Dump-load output | System-sized resistive, air-cooled |
| Cooling | Temperature-controlled fan |
| Protection functions | Overvoltage, overcurrent, overtemperature and overspeed |
| Control logic | Voltage, wind, temperature, current and rotor-speed control |
| Expansion | Optional dual-turbine mode; independent metering and control for each turbine input |
| Matching controller | Smart Charge Controller SCC-5000 |
| Energy flow | Turbine > rectifier > PCB controller > battery/dump load > inverter |
|---|---|
| Operating mode | Off-grid or hybrid-ready operation; no on-grid functionality included |
| Yaw orientation | Passive tail-vane yaw; automatic alignment with wind direction |
| Hybrid compatibility | Compatible with solar and battery systems |
| Package scope | Turbine, PCB controller and dump-load as configured; tower optional and project-specific |
| Not included | Solar panels, batteries, inverter and project-specific cabling unless expressly included in the commercial quotation or sales contract |
Electronic braking, mechanical disc braking and manual emergency stop with automatic fail-safe protection logic.
| Stage 1 | Magnetic / electrical braking for controlled deceleration |
|---|---|
| Stage 2 | Mechanical disc brake, 120 Nm |
| Stage 3 | Manual emergency stop |
| Brake behaviour | Automatic fail-safe protection logic |
| Control priority | Manual stop > overvoltage > wind > temperature > current |
| Slip-ring system | 15-channel, 400 VAC, IP54 |
| Insulation resistance | >100 MΩ |
Designed with reference to IEC 61400-2; EU framework includes LVD 2014/35/EU, EMC 2014/30/EU and Machinery Directive where applicable. Final CE/TÜV status depends on configuration; manufacturing-partner ISO certificates must be valid and verified.
Standards & certifications: IEC 61400-2 · CE · ISO 9001:2015 · IP54 · EMC · LVD · TÜV NORD
CE documentationTechnical datasheet (TIJ-W5000-DS-EN)Good engineering starts before installation: every Watech project begins with a pre-installation site assessment.
| Installation | Ground-mounted tower only; rooftop installation not permitted |
|---|---|
| Tower options | Project-specific lattice or cylindrical tower |
| Reference option | 11 m S235JR lattice tower |
| Reference mass | Approx. 245 kg |
| Anchoring | M24 anchor system |
| Foundation | Preliminary 1.5 x 1.5 x 1.5 m; structural verification required |
| Site assessment | Wind potential, turbulence, tower height and soil conditions must be determined through project-specific structural and geotechnical calculations |
| Engineering note | Local structural approval required |
| Tower heights | 12 – 24 m, chosen per site analysis |
Your power. Our responsibility. Every Tijiwa Watech wind turbine is covered by a 3-year limited warranty program.
| Document | TIJ-W5000-DS-EN | Revision R03 | Issue date 07/2026 |
|---|---|
| Product owner | Tijiwa GmbH |
| Address | Alte Gerberei 4, 35398 Gießen / Hessen, Germany |
| Contact | [email protected] · www.tijiwa.com |
Henüz soru sorulmadı